{"product_id":"micro-focus-x-ray-inspection-system-for-semiconductor-lithium-battery-cells-non-destructive-welding-bubble-crack-defect-detection","title":"Micro Focus X-Ray Inspection System","description":"\u003ch4 data-section-id=\"14lskto\" data-start=\"838\" data-end=\"851\"\u003eMicro Focus X-Ray Inspection System for Semiconductor \u0026amp; Lithium Battery Cells\u003c\/h4\u003e\n\u003ch4 data-section-id=\"14lskto\" data-start=\"838\" data-end=\"851\"\u003eNon-Destructive Welding, Bubble \u0026amp; Crack Defect Detection\u003c\/h4\u003e\n\u003ch2 data-section-id=\"14lskto\" data-start=\"838\" data-end=\"851\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"853\" data-end=\"1053\"\u003eIndustrial \u003cstrong data-start=\"864\" data-end=\"903\"\u003eMicro Focus X-Ray Inspection System\u003c\/strong\u003e designed for high-precision non-destructive internal structure analysis of semiconductor components, lithium battery cells and electronic assemblies.\u003c\/p\u003e\n\u003cp data-start=\"1055\" data-end=\"1083\"\u003eEngineered for detection of:\u003c\/p\u003e\n\u003cul data-start=\"1085\" data-end=\"1188\"\u003e\n\u003cli data-section-id=\"ga8hsf\" data-start=\"1085\" data-end=\"1102\"\u003e\n\u003cp data-start=\"1087\" data-end=\"1102\"\u003eFalse welding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ahq2yq\" data-start=\"1103\" data-end=\"1123\"\u003e\n\u003cp data-start=\"1105\" data-end=\"1123\"\u003eInternal bubbles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tjgt7d\" data-start=\"1124\" data-end=\"1140\"\u003e\n\u003cp data-start=\"1126\" data-end=\"1140\"\u003eMicro cracks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14wwt6i\" data-start=\"1141\" data-end=\"1157\"\u003e\n\u003cp data-start=\"1143\" data-end=\"1157\"\u003eVoid defects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1354tzu\" data-start=\"1158\" data-end=\"1188\"\u003e\n\u003cp data-start=\"1160\" data-end=\"1188\"\u003eStructural inconsistencies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1190\" data-end=\"1260\"\u003eIdeal for advanced electronics and energy storage manufacturing lines.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1lvsvw2\" data-start=\"1267\" data-end=\"1287\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eCore Technology\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1289\" data-end=\"1533\"\u003e\n\u003cli data-section-id=\"wsh6dj\" data-start=\"1289\" data-end=\"1315\"\u003e\n\u003cp data-start=\"1291\" data-end=\"1315\"\u003eMicro Focus X-Ray Tube\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ul1j1s\" data-start=\"1316\" data-end=\"1351\"\u003e\n\u003cp data-start=\"1318\" data-end=\"1351\"\u003eHigh resolution digital imaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1c0pe11\" data-start=\"1352\" data-end=\"1386\"\u003e\n\u003cp data-start=\"1354\" data-end=\"1386\"\u003eReal-time defect visualization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qs5pv3\" data-start=\"1387\" data-end=\"1420\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1420\"\u003eAutomated inspection software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"14s5mcf\" data-start=\"1421\" data-end=\"1461\"\u003e\n\u003cp data-start=\"1423\" data-end=\"1461\"\u003eSPC statistical analysis integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"siyg76\" data-start=\"1462\" data-end=\"1490\"\u003e\n\u003cp data-start=\"1464\" data-end=\"1490\"\u003eZ-axis motorized control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"3bxj13\" data-start=\"1491\" data-end=\"1533\"\u003e\n\u003cp data-start=\"1493\" data-end=\"1533\"\u003eRotating platform with X-arm structure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"yu8k8i\" data-start=\"1540\" data-end=\"1569\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eTechnical Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1571\" data-end=\"1813\"\u003e\n\u003cli data-section-id=\"1t7kc4w\" data-start=\"1571\" data-end=\"1618\"\u003e\n\u003cp data-start=\"1573\" data-end=\"1618\"\u003eEquipment Dimensions: 2160 × 1650 × 1850 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18lm5ly\" data-start=\"1619\" data-end=\"1637\"\u003e\n\u003cp data-start=\"1621\" data-end=\"1637\"\u003eWeight: 2 Tons\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"rz8lup\" data-start=\"1638\" data-end=\"1665\"\u003e\n\u003cp data-start=\"1640\" data-end=\"1665\"\u003ePower Consumption: 5 kW\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1okhox2\" data-start=\"1666\" data-end=\"1696\"\u003e\n\u003cp data-start=\"1668\" data-end=\"1696\"\u003eDetection Accuracy: ±60 μm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ew209d\" data-start=\"1697\" data-end=\"1729\"\u003e\n\u003cp data-start=\"1699\" data-end=\"1729\"\u003eMaximum Tube Voltage: 130 kV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"11mmkv5\" data-start=\"1730\" data-end=\"1756\"\u003e\n\u003cp data-start=\"1732\" data-end=\"1756\"\u003eX-Ray Tube Quantity: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vzp05o\" data-start=\"1757\" data-end=\"1813\"\u003e\n\u003cp data-start=\"1759\" data-end=\"1813\"\u003eInspection Type: Non-Destructive X-Ray Testing (NDT)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"kkdy5j\" data-start=\"1820\" data-end=\"1848\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eInspection Capabilities\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"1850\" data-end=\"2072\"\u003e\n\u003cli data-section-id=\"1fc627f\" data-start=\"1850\" data-end=\"1901\"\u003e\n\u003cp data-start=\"1852\" data-end=\"1901\"\u003eLithium battery electrode full-angle inspection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4qezaw\" data-start=\"1902\" data-end=\"1942\"\u003e\n\u003cp data-start=\"1904\" data-end=\"1942\"\u003eIC chip internal structural analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"9inuku\" data-start=\"1943\" data-end=\"1989\"\u003e\n\u003cp data-start=\"1945\" data-end=\"1989\"\u003eSolder joint internal quality verification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"j249l2\" data-start=\"1990\" data-end=\"2019\"\u003e\n\u003cp data-start=\"1992\" data-end=\"2019\"\u003eVoid and bubble detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"4vf1h6\" data-start=\"2020\" data-end=\"2044\"\u003e\n\u003cp data-start=\"2022\" data-end=\"2044\"\u003eCrack identification\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ml2kv4\" data-start=\"2045\" data-end=\"2072\"\u003e\n\u003cp data-start=\"2047\" data-end=\"2072\"\u003eFalse welding detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"ds1m75\" data-start=\"2079\" data-end=\"2107\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eIndustrial Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2109\" data-end=\"2306\"\u003e\n\u003cli data-section-id=\"1qx5xkd\" data-start=\"2109\" data-end=\"2142\"\u003e\n\u003cp data-start=\"2111\" data-end=\"2142\"\u003eLithium battery manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1j1why8\" data-start=\"2143\" data-end=\"2171\"\u003e\n\u003cp data-start=\"2145\" data-end=\"2171\"\u003eSemiconductor production\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nh5hh6\" data-start=\"2172\" data-end=\"2194\"\u003e\n\u003cp data-start=\"2174\" data-end=\"2194\"\u003ePCB assembly lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1maski7\" data-start=\"2195\" data-end=\"2231\"\u003e\n\u003cp data-start=\"2197\" data-end=\"2231\"\u003eElectronics quality control labs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1stpy7b\" data-start=\"2232\" data-end=\"2269\"\u003e\n\u003cp data-start=\"2234\" data-end=\"2269\"\u003eResearch \u0026amp; Development facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qz8bn9\" data-start=\"2270\" data-end=\"2306\"\u003e\n\u003cp data-start=\"2272\" data-end=\"2306\"\u003eEnergy storage system production\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"ch8sk2\" data-start=\"2313\" data-end=\"2335\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSystem Advantages\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2337\" data-end=\"2588\"\u003e\n\u003cli data-section-id=\"1maevq7\" data-start=\"2337\" data-end=\"2376\"\u003e\n\u003cp data-start=\"2339\" data-end=\"2376\"\u003eNon-destructive internal inspection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tuw8y1\" data-start=\"2377\" data-end=\"2415\"\u003e\n\u003cp data-start=\"2379\" data-end=\"2415\"\u003eHigh precision micro-focus imaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gnp0qy\" data-start=\"2416\" data-end=\"2454\"\u003e\n\u003cp data-start=\"2418\" data-end=\"2454\"\u003eAutomated defect judgment software\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1uhzexp\" data-start=\"2455\" data-end=\"2487\"\u003e\n\u003cp data-start=\"2457\" data-end=\"2487\"\u003eSPC integrated data analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1myox83\" data-start=\"2488\" data-end=\"2520\"\u003e\n\u003cp data-start=\"2490\" data-end=\"2520\"\u003eImproved product consistency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"eoc2xa\" data-start=\"2521\" data-end=\"2544\"\u003e\n\u003cp data-start=\"2523\" data-end=\"2544\"\u003eReduced scrap rates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"dbyi3e\" data-start=\"2545\" data-end=\"2588\"\u003e\n\u003cp data-start=\"2547\" data-end=\"2588\"\u003eIncreased quality assurance reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1mqisqw\" data-start=\"2595\" data-end=\"2624\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eAutomation \u0026amp; Integration\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2626\" data-end=\"2809\"\u003e\n\u003cli data-section-id=\"1mqnqw1\" data-start=\"2626\" data-end=\"2655\"\u003e\n\u003cp data-start=\"2628\" data-end=\"2655\"\u003eFully automated operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1bu1uyd\" data-start=\"2656\" data-end=\"2703\"\u003e\n\u003cp data-start=\"2658\" data-end=\"2703\"\u003eCompatible with industrial production lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pe2eog\" data-start=\"2704\" data-end=\"2733\"\u003e\n\u003cp data-start=\"2706\" data-end=\"2733\"\u003eDigital control interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18rfhyh\" data-start=\"2734\" data-end=\"2765\"\u003e\n\u003cp data-start=\"2736\" data-end=\"2765\"\u003eIndustrial safety enclosure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"jau07i\" data-start=\"2766\" data-end=\"2809\"\u003e\n\u003cp data-start=\"2768\" data-end=\"2809\"\u003eRadiation shielding compliant structure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"cassv6\" data-start=\"2816\" data-end=\"2844\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eOptional Configurations\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul data-start=\"2846\" data-end=\"3027\"\u003e\n\u003cli data-section-id=\"1tqyit\" data-start=\"2846\" data-end=\"2877\"\u003e\n\u003cp data-start=\"2848\" data-end=\"2877\"\u003eHigher voltage tube upgrade\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qfy7sm\" data-start=\"2878\" data-end=\"2919\"\u003e\n\u003cp data-start=\"2880\" data-end=\"2919\"\u003eAdvanced defect recognition AI module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10e3yo0\" data-start=\"2920\" data-end=\"2955\"\u003e\n\u003cp data-start=\"2922\" data-end=\"2955\"\u003eMES production line integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1o5pz9l\" data-start=\"2956\" data-end=\"2988\"\u003e\n\u003cp data-start=\"2958\" data-end=\"2988\"\u003eCustom voltage configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"gfkkrz\" data-start=\"2989\" data-end=\"3027\"\u003e\n\u003cp data-start=\"2991\" data-end=\"3027\"\u003eEnhanced resolution imaging system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Industrial Index","offers":[{"title":"False Welding \/ Bubble \/ Crack Defect Detection","offer_id":57431963173248,"sku":"5655912556426","price":31802.73,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0977\/4445\/4016\/files\/2_008b06fc-3d21-4ec0-acff-21e2a3dd19dc.png?v=1771923503","url":"https:\/\/industrial-index.com\/products\/micro-focus-x-ray-inspection-system-for-semiconductor-lithium-battery-cells-non-destructive-welding-bubble-crack-defect-detection","provider":"Industrial Index","version":"1.0","type":"link"}